Additional Description 1
<ol style='list-style-type:upper-roman'> <li style='text-align:justify'><strong><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>SCOPE OF WORK</span></span></strong> <ol> <li style='list-style-type:none'> <ol> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Complete an initial assessment of all generators and establish maintenance and service records to include schedules per generator based on guidelines outlined in this scope of work and in adherence with specific equipment manufacturer specifications.</span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='2'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Submit service and repair records to NYCHA Administration upon completion of work and as requested.</span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='3'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Provide quarterly schedule for all maintenance per generator. This schedule must be submitted prior to the next quarter and approved by a NYCHA Administrator.</span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='4'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Minor Preventative Maintenance: For each Generator, perform four (4) Minor Preventative Maintenance visits annually, once per quarter. Each Minor Preventative Maintenance visit shall take place within seventy-five (75) to ninety-one (91) days after the last Minor Preventative Maintenance visit. Please note the 4<sup>th</sup> quarterly inspection will be incorporated into the one annual service visit. All work shall follow specific equipments recommended maintenance and service guidelines.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol style='list-style-type:lower-alpha'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Vendor shall supply all necessary tools, parts, and materials. </span></span></span></li> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>During each Minor Preventative Maintenance visit on each Generator, the Vendor shall perform typical generator maintenance in accordance </span>with the O&M manual and <span style='background-color:#faf9f8'>with industry best practice, including but not limited to the following tasks: </span></span></span></li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='3' style='list-style-type:lower-alpha'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Cooling Systems: </span></span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Visual inspection of radiator or heat exchanger for leaks, damage, and obstruction. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check jacket water coolant level and take coolant sample for analysis. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Test coolant for proper antifreeze percentage.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check jacket water heater for proper operation and adjust thermostat setting as needed.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect condition of radiator cap, gasket and sealing surface.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Visual inspection of water pump and cooling system gaskets for leaks. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check belt tension and inspect for cracking and fraying if accessibility without disassembly permits.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect pulleys for excessive wear and lubricate hub bearings as needed. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect flexible water connections for cracking, leaks, and pliability. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Tighten hose clamps as needed. </span></span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='4' style='list-style-type:lower-alpha'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Lubrication System</span>. </span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check and top off oil level. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check for excessive crankcase blow-by with engine running. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Visual inspection of front and rear crankshaft seals and lubrication system gaskets for leaks. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect oil hose and connections for cracking, leaks, and pliability. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Take crankcase oil sample</span>; t<span style='background-color:#faf9f8'>esting should be as per manufacturers guidance by submitting sample to a qualified testing laboratory or using the Engine Manufacturers Supplied Test kit. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Consolidate the results of all Generator oil samples on a quarterly basis in spread sheet form detailing findings. </span></span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='5' style='list-style-type:lower-alpha'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Inspect <span style='background-color:#faf9f8'>Fuel System </span></span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect gas pressure regulator and check for leaks. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Drain water from water separator if applicable.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check gas line</span>, Maxon valves and regulators <span style='background-color:#faf9f8'>for leaks. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check electronic governor connections and actuator. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect gas lines</span>, Maxon valves and regulators <span style='background-color:#faf9f8'>for cracks, leaks, and proper line bracket support. </span></span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='6' style='list-style-type:lower-alpha'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Starting System </span></span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Top off electrolyte level in batteries with dis tilled water.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check and record battery charger/alternator for proper charge rate. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check for proper cranking te</span>rm<span style='background-color:#faf9f8'>ination upon starting. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Clean and apply corrosion inhibitor to the terminals of lead acid batteries as needed. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Tighten battery cable connections as needed. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect and tighten starter motor, connections, and wiring. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check and record battery voltage dip level during over crank </span>t<span style='background-color:#faf9f8'>est for minimum voltage required to maintain controls during start-up. </span></span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='7' style='list-style-type:lower-alpha'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Exhaust System </span></span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect flexible exhaust coupling for cracks, excessive leakage, broken, or missing hardware.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect exterior of exhaust manifolds for oil/fuel slobbering (signs of wet stacking). </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect exhaust rain protection and exhaust outlet screening. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Drain water in exhaust moisture traps.</span></span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='8' style='list-style-type:lower-alpha'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Air Intake System </span></span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect air filters for plugging and deterioration, clean if required. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check all air intake piping for damage and loose connections. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect air cleaner seal for pliability and sealing and clean if necessary. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect turbocharger for excessive endplay clearance (if accessible) and seal leakage. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Walk around inspection of complete Generator installation. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect Generator set vibration isolators. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check for abnormal noise or vibration. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Re-check for oil and coolant leaks with engine running. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check for proper operation of remote fan motors, thermostats, circulating pumps, and solenoid valves. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check inlet and discharge louvers for proper operation with engine running and stopped. </span></span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol style='list-style-type:lower-roman'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Control Panel </span></span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Operational check of illumination and safety lamps.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check electronic control panels for fault codes. Clear any unnecessary codes, notify customer of any codes that need to be addressed. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check proper operation of engine and generator instruments with generator running. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Adjust governor control for optimum performance and frequency.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Adjust voltage regulator for proper voltage.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check for and tighten loose terminals on the generator and the Generator control panel. Check tightness of relays in the generator control panel. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Inspect for excessive dirt accumulation and clean as needed. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Test auto-start system. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Test safeties and pre-alarms on engine/generator control and annunciator panels.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check operation of automatic sync equipment with customer authorization. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Place generator online and check operation of transfer switches. This will be done only with the consent of the Technical Resources Department. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Upon Completion of Service reset all controls to automatic. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Set circuit breaker to correct position. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check that gas valves are in correct position. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check that battery charger is on. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check that louver controls are on. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Check that jacket water heater is on. </span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Provide an electronic checklist confirming all items were completed along with recording any measurements, descriptions of conditions, run</span> <span style='background-color:#faf9f8'>times, and any notes. The checklist should also include the name of the service technician and date.</span></span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='10' style='list-style-type:lower-alpha'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Gas Booster Pumps, Control Panels and Maxon Valves</span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Check operations.</span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Service.</span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Repair and replace.</span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='11' style='list-style-type:lower-alpha'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Fire Safety Equipment</span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Inspection and maintenance of gas Co2 detection systems. QEL Gas Monitoring System and detection devices and calibration, when necessary, as per manufacturers specifications in accordance with NFPA 12 and 1 RCNY 908-01 Chapter 900.</span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='12' style='list-style-type:lower-alpha'> <li style='text-align:justify' value='50'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Ventilation Systems</span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Inspect, maintain, repair, and/or replace components of generator room ventilation systems.</span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='13' style='list-style-type:lower-alpha'> <li style='text-align:justify' value='1000'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Electric and/or gas heaters</span></span> <ol style='list-style-type:lower-roman'> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Inspect, service, maintain and repair electric and/or gas heaters within the generator room and/or Generator Enclosure, Gas Booster rooms, Electric Automatic Transfer Switch (ATS) rooms.</span></span></li> </ol> </li> </ol> </li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> l. <span style='font-family:Arial,Helvetica,sans-serif; font-size:16px'>Uninterrupted Power Source (UPS)</span></li> <li style='list-style-type:none'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'> i Check operation, service and repair/replace as needed.</span></span></li> </ol> </li> </ol> </li></ol><ul> <li style='list-style-type:none'> <ul> <li style='list-style-type:none'> <ul> <li style='list-style-type:none'> m. <span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Automatic Transfer Switches</span></span></li> <li style='list-style-type:none'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'> i. Inspect and check operation.</span></span></li> <li style='list-style-type:none'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'> ii. Repair and/or replace as needed.</span></span></li> </ul> </li> </ul> </li></ul><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='5'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Major Preventative Maintenance: Once per year during a Minor Preventative Maintenance visit, Vendor shall perform the following Major Preventative Maintenance tasks on each Generator: </sp
Additional Description 2
an></span></span> <ol style='list-style-type:lower-alpha'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Change engine oil and filters.</span></span></span></li> <li><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Check and replace spark plugs and wiring as needed.</span></span></li> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Change primary and secondary fuel filters. </span></span></span></li> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Properly dispose of waste oil and filters. </span></span></span></li> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Lubricate fan drive if accessible. </span></span></span></li> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Lubricate governor linkage. </span></span></span></li> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Lubricate generator bearing if accessible. </span></span></span></li> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Clean crankcase breather.</span></span></span></li> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Inspect & test ATS and tighten ATS lugs.</span></span></li> <li style='text-align:justify' value='10'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Provide an electronic checklist confirming all items were completed along with recording any measurements, descriptions of conditions, run times, and any note s. The checklist should also include the name of the service technician and date. </span></span></span></li> </ol> </li> </ol> </li> </ol> </li> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='6'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Vendor shall supply all necessary tools, parts, and materials when performing Major Preventative maintenance.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='7'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>All work shall follow specific equipments recommended maintenance and service guidelines.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='8'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Emergency Repair: The Vendor shall provide a 24-hour, 7 day per week on-call service phone number to handle NYCHA customer service needs and to allow NYCHA to request emergency Generator repairs. </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='9'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Vendor shall supply all necessary tools, parts, and materials in connection with Emergency Maintenance. All Emergency Maintenance is subject to NYCHA's prior approval.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='10'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Repair Maintenance: If a Generator needs a repair that Vendor cannot perform during a Minor Preventative Maintenance visit or during Emergency Maintenance, Vendor shall schedule with NYCHA an alternate time for the repair. Vendor shall supply all necessary tools, parts, and materials in connection with Repair Maintenance. All Repair Maintenance is subject to NYCHA's prior approval.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='11'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Other Maintenance Requirements: When performing any form of Generator Maintenance, Vendor shall comply with the following rules and procedures: </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='12'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Responsibility to Maintain - Upon installation and acceptance of each Generator, NYCHA will notify the Vendor in writing. Once notified, the Vendor shall have the responsibility to perform Generator Maintenance for each Generator listed in the notice as outlined in this Agreement. </span></span></span></li> </ol> </li> </ol> </li></ol><p style='margin-left:144px'> </p><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='13'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Equipment and Supplies -</span> <span style='background-color:#faf9f8'>The Vendor shall furnish all tools, materials, supplies and equipment to perform the Generator Maintenance. The Vendor shall notify NYCHA immediately in the event of any NYCHA-owned equipment failure or unsafe working condition. </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='14'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Waste/Materials Disposal</span> <span style='background-color:#faf9f8'>-</span> <span style='background-color:#faf9f8'>Vendor shall dispose of all waste, debris, and excess materials generated during the Generator Maintenance in accordance with all applicable regulations and laws. Vendor is solely responsible for all fees, costs, damages, fines, or penalties related to the disposal of waste and materials. Under no circumstances shall Vendor dispose of waste, debris, or excess materials on NYCHA property.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='15'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>The Vendor shall ensure that employees and/or subconsultants comply with all New York regulations and practices.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='16'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>The Vendor's employees and/or subconsultants shall conduct themselves in a workmanlike manner while performing Services. Vendor employees and/or subconsultants shall be courteous, neat in appearance and always wear visible vendor identification and a name tag. </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='17'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>NYCHA 's Contract Administrator or appointed representative shall inspect Generator Maintenance Services performed by the Vendor on a regular basis. In the event of work performance deficiencies, the Contract Administrator shall notify the Vendor. Notification may be verbal or written. NYCHA will require the Vendor to rectify the deficiency within 24 hours. </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='18'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>The Vendor shall ensure that NYCHA always has a complete and up-to-date list of the names of employees and/or subconsultant employees who will perform Generator Maintenance.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='19'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>The Vendor shall not remove or consume any property belonging to NYCHA or NYCHA employees or residents. This includes any articles that may be deposited for disposal in trash receptacles.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='20'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Equipment and supplies belonging to NYCHA shall not be transferred from one job site to another by the Vendor without permission of NYCHA 's Contract Administrator. </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='21'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>The Vendor and its employees may not use NYC</span>H<span style='background-color:#faf9f8'>A property, including telephones, for personal use unless given permission by staff at the Development. </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='22'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Vendor's employees and/or subconsultants shall not smoke on NYCHA property.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='23'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>If NYCHA provides Vendor NYCHA keys or key cards to gain access to a Development, the Vendor shall not make duplicates of </span>s<span style='background-color:#faf9f8'>uch keys or key cards. The Vendor shall ensure that all gates, doors, and hatches giving access to NYCHA facilities are secured. The Vendor shall immediately report to the Contract Administrator (or other designated representative if during non-business hours) any damage or potential hazard involving NYCHA property. Hazardous conditions relating to a Generator(s) shall be immediately remedied or secured to prevent further damage and/or to protect visitors from injury. </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='24'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Vendor shall report incidents, altercations or accidents involving facility visitors, Vendor's employees, NYCHA employees or residents to the Contract Administrator and Property Management in a timely manner. The Contract Administrator, at his/her discretion, may require a written report from the Vendor describing the incident or accident. </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='25'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Any person performing Generator Maintenance must be licensed/certified to do so in accordance with any relevant laws and regulations, including service technician journey level licensing and training certifications. </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='26'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>Whenever Generator Maintenance is performed, the service technician shall provide to the Contract Administrator a detailed report of the work done clearly identifying the condition of the Generator equipment and receive signature for the service performed from the Contract Administrator or designee. </span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='27'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>The Vendor shall advise the Contract Administrator of any necessary repairs and an approximate cost to complete the repairs if those repairs fall outside of Minor or Major Preventative Maintenance. Approval from the Contract Administrator shall be necessary before any repairs can take place.</span></span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='28'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>In the event work is performed after normal business hours and/or on an emergency basis, a written estimate will be accepted for review. Once work is completed a statement of services will be submitted to the Technical Resources Department for review and approval.</span></span></li> </ol> </li> </ol> </li></ol><ol> <li style='list-style-type:none'> <ol> <li style='list-style-type:none'> <ol start='29'> <li style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><span style='background-color:#faf9f8'>The Vendor shall keep records of all Generator Maintenance and such records must be accessible and submitted to NYCHA Contract Administrator or NYCHA staff on an as needed and on an ongoing basis as quarterly and annual service is completed per unit. </span></span></span></li> </ol> </li> </ol> </li></ol><p style='text-align:justify'><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><strong>TERM: </strong>3 years plus two one-year extensions (at the discretion of NYCHA).</span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><strong>Section 3 and M/WBE: </strong>Please be advised that the Section 3 REO & OEO Plans and the M/WBE Utilization Plan & Waiver and other related documentation must be uploaded via eComply, https://nycha.ecomply.us/. Do not include Section 3 or M/WBE documentation within your bid submission via iSupplier. For assistance with eComply log-in, please contact eComply Tech support at support@ecomplysolutions.com. For assistance with M/WBE Utilization Plan and Section 3 REO/OEO Plan submission in eComply, please contact NYCHAs SMP Vendor Diversity team at eComply.support@nycha.nyc.gov<u>.</u> </span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><strong>Pre-Bid Conference</strong>. A non-mandatory virtual Pre-Bid Conference will be held on <strong>April 1st, 2025 at 10:00 AM</strong> and will be conducted remotely via Microsoft Teams meeting. Although attendance is not mandatory at the Pre-Bid Conference, it is strongly recommended that all interested Bidders attend, and that Bidders thoroughly review bid documents in advance of the meeting. </span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>To participate in the Pre-Bid Conference, please follow the instructions below:</span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Microsoft Teams Meeting</span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Join on your computer or mobile app: click to join meeting</span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><strong>Option 1</strong>: Copy and paste the below in browser:</span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>teams.microsoft.com/l/meetup-join/19%3ameeting_ZjE3YjhmZjYtNWRhOC00MjRlLTgwYjQtZDAxNTY5ZGY4ZGI3%40thread.v2/0?context=%7b%22Tid%22%3a%22709ab558-a73c-4f8f-98ad-20bb096cd0f8%22%2c%22Oid%22%3a%22d3ad4d7d-b23c-46b6-a970-2e5863640413%22%7d</span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><strong>Meeting ID</strong>: 267 176 607 218 <strong>Passcode</strong>: sv2rg98Q</span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><strong>Option 2</strong>: Call in (audio only) +1 646-838-1534,267176607218# United States, New York City</span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><strong>Phone conference ID</strong>: 267 176 607 218 #</span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'><strong>RFQ Timeline:</strong></span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>RFQ Question Submission Deadline 4/4/25 at 2:00PM</span></span></p><p><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>Question and Answer Release Date 4/11</span></span><span style='font-size:16px'><span style='font-family:Arial,Helvetica,sans-serif'>/25 at 2:00PM</span></span></p><p> </p>