Watershed Water Quality - Hydrology Qualifiers

Qualifiers, notes, and additional information regarding the sample data provided or omitted.

Environment Department of Environmental Protection (DEP) Dataset shus-qn78 5 fields
DOWNLOAD CSV
Dataset fields
Showing 50 real records
NCG
Sample Site: NCG • Sample Id: G-2401860-10 • Analyte: Nitrogen, Total (as N)
Sample Site
NCG
Sample Id
G-2401860-10
Analyte
Nitrogen, Total (as N)
Sample Date
2024-06-03T00:00:00.000
Qualifier
QC failed. QCS failure for Nitrogen
SCL
Sample Site: SCL • Sample Id: K-2401957-02 • Analyte: Ammonia (as N)
Sample Site
SCL
Sample Id
K-2401957-02
Analyte
Ammonia (as N)
Sample Date
2024-06-03T00:00:00.000
Qualifier
Air spike or irregular peak; sample reanalyzed
CDG
Sample Site: CDG • Sample Id: G-2401860-05 • Analyte: Nitrogen, Total (as N)
Sample Site
CDG
Sample Id
G-2401860-05
Analyte
Nitrogen, Total (as N)
Sample Date
2024-06-03T00:00:00.000
Qualifier
QC failed. QCS failure for Nitrogen
CEBHG
Sample Site: CEBHG • Sample Id: G-2401923-01 • Analyte: Nitrogen, Total (as N)
Sample Site
CEBHG
Sample Id
G-2401923-01
Analyte
Nitrogen, Total (as N)
Sample Date
2024-06-03T00:00:00.000
Qualifier
QC failed. QCS failure for Nitrogen
CTNBG
Sample Site: CTNBG • Sample Id: G-2401860-02 • Analyte: Nitrogen, Total (as N)
Sample Site
CTNBG
Sample Id
G-2401860-02
Analyte
Nitrogen, Total (as N)
Sample Date
2024-06-03T00:00:00.000
Qualifier
QC failed. QCS failure for Nitrogen
CCBHG
Sample Site: CCBHG • Sample Id: G-2401860-03 • Analyte: Nitrogen, Total (as N)
Sample Site
CCBHG
Sample Id
G-2401860-03
Analyte
Nitrogen, Total (as N)
Sample Date
2024-06-03T00:00:00.000
Qualifier
QC failed. QCS failure for Nitrogen
ASP M-1 Conf
Sample Site: ASP M-1 Conf • Sample Id: K-2401886-05 • Analyte: Solids, Total Suspended
Sample Site
ASP M-1 Conf
Sample Id
K-2401886-05
Analyte
Solids, Total Suspended
Sample Date
2024-05-28T00:00:00.000
Qualifier
Site insufficient flow or elevation
CROSSRVVC
Sample Site: CROSSRVVC • Sample Id: E-2401863-03 • Analyte: Field Conductance
Sample Site
CROSSRVVC
Sample Id
E-2401863-03
Analyte
Field Conductance
Sample Date
2024-05-28T00:00:00.000
Qualifier
The duplicate analysis was not within the control limits.
ASP M-1 Conf
Sample Site: ASP M-1 Conf • Sample Id: K-2401886-05 • Analyte: Turbidity
Sample Site
ASP M-1 Conf
Sample Id
K-2401886-05
Analyte
Turbidity
Sample Date
2024-05-28T00:00:00.000
Qualifier
Site insufficient flow or elevation
CROSSRVVC
Sample Site: CROSSRVVC • Sample Id: E-2401863-03 • Analyte: Chlorophyll RFU
Sample Site
CROSSRVVC
Sample Id
E-2401863-03
Analyte
Chlorophyll RFU
Sample Date
2024-05-28T00:00:00.000
Qualifier
The duplicate analysis was not within the control limits.
CBS
Sample Site: CBS • Sample Id: G-2401809-08 • Analyte: Soluble Reactive Phosphorus (as P)
Sample Site
CBS
Sample Id
G-2401809-08
Analyte
Soluble Reactive Phosphorus (as P)
Sample Date
2024-05-28T00:00:00.000
Qualifier
Bottle G-2401809-08-02 was cancelled because sample was collected in incorrect bottle type and was not filtered in the field. Sample in filtered bottle G-2401809-08-07 was used to measure associated analytes (NOx and Orthophosphate).
ASP
Sample Site: ASP • Sample Id: K-2401886-04 • Analyte: Coliform, Fecal
Sample Site
ASP
Sample Id
K-2401886-04
Analyte
Coliform, Fecal
Sample Date
2024-05-28T00:00:00.000
Qualifier
Site insufficient flow or elevation
CBS
Sample Site: CBS • Sample Id: G-2401809-08 • Analyte: UV-254
Sample Site
CBS
Sample Id
G-2401809-08
Analyte
UV-254
Sample Date
2024-05-28T00:00:00.000
Qualifier
Bottle G-2401809-08-02 was cancelled because sample was collected in incorrect bottle type and was not filtered in the field. Sample in filtered bottle G-2401809-08-07 was used to measure associated analytes (NOx and Orthophosphate).
ASP
Sample Site: ASP • Sample Id: K-2401886-04 • Analyte: Temperature
Sample Site
ASP
Sample Id
K-2401886-04
Analyte
Temperature
Sample Date
2024-05-28T00:00:00.000
Qualifier
Site insufficient flow or elevation
ASP M-1 Conf
Sample Site: ASP M-1 Conf • Sample Id: K-2401886-05 • Analyte: Temperature
Sample Site
ASP M-1 Conf
Sample Id
K-2401886-05
Analyte
Temperature
Sample Date
2024-05-28T00:00:00.000
Qualifier
Site insufficient flow or elevation
ASP
Sample Site: ASP • Sample Id: K-2401886-04 • Analyte: Solids, Total Suspended
Sample Site
ASP
Sample Id
K-2401886-04
Analyte
Solids, Total Suspended
Sample Date
2024-05-28T00:00:00.000
Qualifier
Site insufficient flow or elevation
CBS
Sample Site: CBS • Sample Id: G-2401809-08 • Analyte: Nitrogen, Total (as N)
Sample Site
CBS
Sample Id
G-2401809-08
Analyte
Nitrogen, Total (as N)
Sample Date
2024-05-28T00:00:00.000
Qualifier
QC failed
NCG
Sample Site: NCG • Sample Id: G-2401887-01 • Analyte: Nitrogen, Total Dissolved (as N)
Sample Site
NCG
Sample Id
G-2401887-01
Analyte
Nitrogen, Total Dissolved (as N)
Sample Date
2024-05-28T00:00:00.000
Qualifier
QC failed
CBS
Sample Site: CBS • Sample Id: G-2401809-08 • Analyte: Nitrate/Nitrite (as N)
Sample Site
CBS
Sample Id
G-2401809-08
Analyte
Nitrate/Nitrite (as N)
Sample Date
2024-05-28T00:00:00.000
Qualifier
Bottle G-2401809-08-02 was cancelled because sample was collected in incorrect bottle type and was not filtered in the field. Sample in filtered bottle G-2401809-08-07 was used to measure associated analytes (NOx and Orthophosphate).
ASP
Sample Site: ASP • Sample Id: K-2401886-04 • Analyte: Turbidity
Sample Site
ASP
Sample Id
K-2401886-04
Analyte
Turbidity
Sample Date
2024-05-28T00:00:00.000
Qualifier
Site insufficient flow or elevation
LONGPD1
Sample Site: LONGPD1 • Sample Id: E-2401771-03 • Analyte: Ammonia (as N)
Sample Site
LONGPD1
Sample Id
E-2401771-03
Analyte
Ammonia (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
The end-of-run LOQ was not within 50-150%. Instrument heater error. No LOQ associated with samples.
MIKE2
Sample Site: MIKE2 • Sample Id: E-2401770-01 • Analyte: Nitrogen, Total Dissolved (as N)
Sample Site
MIKE2
Sample Id
E-2401770-01
Analyte
Nitrogen, Total Dissolved (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
QC failed
MIDBR3
Sample Site: MIDBR3 • Sample Id: E-2401770-02 • Analyte: Nitrogen, Total Dissolved (as N)
Sample Site
MIDBR3
Sample Id
E-2401770-02
Analyte
Nitrogen, Total Dissolved (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
QC failed
HORSEPD12
Sample Site: HORSEPD12 • Sample Id: E-2401770-03 • Analyte: Nitrogen, Total Dissolved (as N)
Sample Site
HORSEPD12
Sample Id
E-2401770-03
Analyte
Nitrogen, Total Dissolved (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
QC failed
GYPSYTRL1
Sample Site: GYPSYTRL1 • Sample Id: E-2401770-04 • Analyte: Ammonia (as N)
Sample Site
GYPSYTRL1
Sample Id
E-2401770-04
Analyte
Ammonia (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
The end-of-run LOQ was not within 50-150%. Instrument heater error. No LOQ associated with samples.
HORSEPD12
Sample Site: HORSEPD12 • Sample Id: E-2401770-03 • Analyte: Ammonia (as N)
Sample Site
HORSEPD12
Sample Id
E-2401770-03
Analyte
Ammonia (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
The end-of-run LOQ was not within 50-150%. Instrument heater error. No LOQ associated with samples.
WESTBR7
Sample Site: WESTBR7 • Sample Id: E-2401771-01 • Analyte: Nitrogen, Total Dissolved (as N)
Sample Site
WESTBR7
Sample Id
E-2401771-01
Analyte
Nitrogen, Total Dissolved (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
QC failed
MUSCOOT10
Sample Site: MUSCOOT10 • Sample Id: E-2401771-04 • Analyte: Ammonia (as N)
Sample Site
MUSCOOT10
Sample Id
E-2401771-04
Analyte
Ammonia (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
The end-of-run LOQ was not within 50-150%. Instrument heater error. No LOQ associated with samples.
MUSCOOT10
Sample Site: MUSCOOT10 • Sample Id: E-2401771-04 • Analyte: Nitrogen, Total Dissolved (as N)
Sample Site
MUSCOOT10
Sample Id
E-2401771-04
Analyte
Nitrogen, Total Dissolved (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
QC failed
MIDBR3
Sample Site: MIDBR3 • Sample Id: E-2401770-02 • Analyte: Ammonia (as N)
Sample Site
MIDBR3
Sample Id
E-2401770-02
Analyte
Ammonia (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
The end-of-run LOQ was not within 50-150%. Instrument heater error. No LOQ associated with samples.
WESTBR7
Sample Site: WESTBR7 • Sample Id: E-2401771-01 • Analyte: Organic Carbon, Dissolved
Sample Site
WESTBR7
Sample Id
E-2401771-01
Analyte
Organic Carbon, Dissolved
Sample Date
2024-05-22T00:00:00.000
Qualifier
This sample is associated with a spiked sample result that was above the high calibrant. The spike recovery was calculated using an extrapolated value.
HORSEPD12
Sample Site: HORSEPD12 • Sample Id: E-2401770-03 • Analyte: Phosphorus, Total Dissolved (as P)
Sample Site
HORSEPD12
Sample Id
E-2401770-03
Analyte
Phosphorus, Total Dissolved (as P)
Sample Date
2024-05-22T00:00:00.000
Qualifier
No MS/MSD associated with this batch.
WESTBRR
Sample Site: WESTBRR • Sample Id: E-2401771-02 • Analyte: Ammonia (as N)
Sample Site
WESTBRR
Sample Id
E-2401771-02
Analyte
Ammonia (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
The end-of-run LOQ was not within 50-150%. Instrument heater error. No LOQ associated with samples.
GYPSYTRL1
Sample Site: GYPSYTRL1 • Sample Id: E-2401770-04 • Analyte: Nitrogen, Total Dissolved (as N)
Sample Site
GYPSYTRL1
Sample Id
E-2401770-04
Analyte
Nitrogen, Total Dissolved (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
QC failed
MIKE2
Sample Site: MIKE2 • Sample Id: E-2401770-01 • Analyte: Sodium, Dissolved
Sample Site
MIKE2
Sample Id
E-2401770-01
Analyte
Sodium, Dissolved
Sample Date
2024-05-22T00:00:00.000
Qualifier
Data reanalyzed due to result above calibration range.
GYPSYTRL1
Sample Site: GYPSYTRL1 • Sample Id: E-2401770-04 • Analyte: Phosphorus, Total Dissolved (as P)
Sample Site
GYPSYTRL1
Sample Id
E-2401770-04
Analyte
Phosphorus, Total Dissolved (as P)
Sample Date
2024-05-22T00:00:00.000
Qualifier
No MS/MSD associated with this batch.
WESTBR7
Sample Site: WESTBR7 • Sample Id: E-2401771-01 • Analyte: Ammonia (as N)
Sample Site
WESTBR7
Sample Id
E-2401771-01
Analyte
Ammonia (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
The end-of-run LOQ was not within 50-150%. Instrument heater error. No LOQ associated with samples.
WESTBR7
Sample Site: WESTBR7 • Sample Id: E-2401771-01 • Analyte: Organic Carbon, Dissolved
Sample Site
WESTBR7
Sample Id
E-2401771-01
Analyte
Organic Carbon, Dissolved
Sample Date
2024-05-22T00:00:00.000
Qualifier
The spike analysis was not within the control limits.
MUSCOOT10
Sample Site: MUSCOOT10 • Sample Id: E-2401771-04 • Analyte: Sodium, Dissolved
Sample Site
MUSCOOT10
Sample Id
E-2401771-04
Analyte
Sodium, Dissolved
Sample Date
2024-05-22T00:00:00.000
Qualifier
Data reanalyzed due to result above calibration range.
MIDBR3
Sample Site: MIDBR3 • Sample Id: E-2401770-02 • Analyte: Organic Carbon, Dissolved
Sample Site
MIDBR3
Sample Id
E-2401770-02
Analyte
Organic Carbon, Dissolved
Sample Date
2024-05-22T00:00:00.000
Qualifier
This sample was not preserved within 15 minutes of sample collection. acid added in laboratory
MIDBR3
Sample Site: MIDBR3 • Sample Id: E-2401770-02 • Analyte: Nitrogen, Total Dissolved (as N)
Sample Site
MIDBR3
Sample Id
E-2401770-02
Analyte
Nitrogen, Total Dissolved (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
QC failed
LONGPD1
Sample Site: LONGPD1 • Sample Id: E-2401771-03 • Analyte: Sodium, Dissolved
Sample Site
LONGPD1
Sample Id
E-2401771-03
Analyte
Sodium, Dissolved
Sample Date
2024-05-22T00:00:00.000
Qualifier
This sample is associated with a spiked sample result that was above the high calibrant. The spike recovery was calculated using an extrapolated value.
MIKE2
Sample Site: MIKE2 • Sample Id: E-2401770-01 • Analyte: Ammonia (as N)
Sample Site
MIKE2
Sample Id
E-2401770-01
Analyte
Ammonia (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
The end-of-run LOQ was not within 50-150%. Instrument heater error. No LOQ associated with samples.
MIDBR3
Sample Site: MIDBR3 • Sample Id: E-2401770-02 • Analyte: Nitrogen, Total Dissolved (as N)
Sample Site
MIDBR3
Sample Id
E-2401770-02
Analyte
Nitrogen, Total Dissolved (as N)
Sample Date
2024-05-22T00:00:00.000
Qualifier
This sample was not preserved within 15 minutes of sample collection. acid added in laboratory
BOYDR
Sample Site: BOYDR • Sample Id: E-2401767-01 • Analyte: UV-254
Sample Site
BOYDR
Sample Id
E-2401767-01
Analyte
UV-254
Sample Date
2024-05-21T00:00:00.000
Qualifier
Bottle prep failure
BOYDR
Sample Site: BOYDR • Sample Id: E-2401767-05 • Analyte: UV-254
Sample Site
BOYDR
Sample Id
E-2401767-05
Analyte
UV-254
Sample Date
2024-05-21T00:00:00.000
Qualifier
initial temperature was not taken at the temp blank site, could not verify cooling
CBS
Sample Site: CBS • Sample Id: G-2401716-05 • Analyte: Bromodichloromethane (potential)
Sample Site
CBS
Sample Id
G-2401716-05
Analyte
Bromodichloromethane (potential)
Sample Date
2024-05-20T00:00:00.000
Qualifier
LCS/LCSD RPD exceeds control limits.
PBKG
Sample Site: PBKG • Sample Id: G-2401638-01 • Analyte: Nitrate/Nitrite (as N)
Sample Site
PBKG
Sample Id
G-2401638-01
Analyte
Nitrate/Nitrite (as N)
Sample Date
2024-05-20T00:00:00.000
Qualifier
The duplicate analysis was not within the control limits.
ASP
Sample Site: ASP • Sample Id: K-2401777-04 • Analyte: Temperature
Sample Site
ASP
Sample Id
K-2401777-04
Analyte
Temperature
Sample Date
2024-05-20T00:00:00.000
Qualifier
Site insufficient flow or elevation
NCG
Sample Site: NCG • Sample Id: G-2401638-05 • Analyte: Bromodichloromethane (potential)
Sample Site
NCG
Sample Id
G-2401638-05
Analyte
Bromodichloromethane (potential)
Sample Date
2024-05-20T00:00:00.000
Qualifier
LCS/LCSD RPD exceeds control limits.